Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Arch Dis Child Fetal Neonatal Ed ; 103(1): F49-F55, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28663283

RESUMO

OBJECTIVE: To verify whether the use of the T-piece resuscitator compared with the self-inflating bag in preterm infants ventilated at birth modifies survival to hospital discharge without major morbidities. DESIGN: Pragmatic prospective cohort study. SETTING: 20 Brazilian university hospitals of Brazilian Network on Neonatal Research. Patients were 1962 inborn infants in 2014-2015 ventilated at birth with 23-33' weeks gestation and birth weight 400-1499 g without malformations. Patients transferred until the 27th day after birth were excluded. INTERVENTIONS: Positive pressure ventilation at birth with T-piece resuscitator or self-inflating bag without positive end expiratory pressure valve. Intervention with ventilation followed the Brazilian Society of Pediatrics guidelines. The choice of the equipment was at the neonatologist's discretion in each delivery. The main outcome measures were survival to hospital discharge without bronchopulmonary dysplasia, severe peri-intraventricular haemorrhage and periventricular leucomalacia. Logistic regression adjusted for confounding variables was applied for main outcome. RESULTS: 1456 (74%) were only ventilated with T-piece resuscitator and 506 (26%) with the self-inflating bag. The characteristics of those ventilated with T-Piece resuscitator versus self-inflating bag were birth weight 969 ± 277 vs 941 ± 279 g, gestational age 28.2±2.5 vs 27.8±2.7 weeks and survival to hospital discharge without major morbidities 47% vs 35%. Logistic regression adjusted for maternal characteristics, obstetric and neonatal morbidities showed that the T-piece resuscitator increased the chance of survival to hospital discharge without major morbidities (OR=1.38; 95% CI 1.06 to 1.80; Hosmer-Lemeshow goodness of fit: 0.695). CONCLUSION: This study is the first that highlights the effectiveness of T-piece resuscitator ventilation in improving relevant outcomes in preterm neonates.


Assuntos
Doenças do Prematuro , Recém-Nascido Prematuro/fisiologia , Respiração com Pressão Positiva , Respiração Artificial , Ventiladores Mecânicos , Brasil/epidemiologia , Estudos de Coortes , Desenho de Equipamento , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Doenças do Prematuro/epidemiologia , Doenças do Prematuro/etiologia , Insuflação/métodos , Masculino , Alta do Paciente/estatística & dados numéricos , Respiração com Pressão Positiva/instrumentação , Respiração com Pressão Positiva/métodos , Gravidez , Resultado da Gravidez/epidemiologia , Nascimento Prematuro/epidemiologia , Respiração Artificial/instrumentação , Respiração Artificial/métodos , Análise de Sobrevida , Ventiladores Mecânicos/efeitos adversos , Ventiladores Mecânicos/normas
2.
Rev. bras. saúde matern. infant ; 16(4): 467-473, Oct.-Dec. 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-844231

RESUMO

Abstract Introduction: several birth defects associated to congenital Zika virus infection have been reported, although the clinical features have not been fully characterized. Description: this is the first case report on unilateral diaphragmatic paralysis diagnosed on a neonate with congenital Zika confirmed by the examination of the amniotic fluid through polymerase chain reaction (ZIKV RT-PCR) and the examination of cerebrospinal fluid by serological test (IgM ZIKV-ELISA) after birth. The main manifestations detected by intrauterine ultrasound were: microcephaly, ventriculomegaly, intracranial calcifications, enlarged cisterna magna, increased amniotic fluid index and fetal akinesia syndrome. The newborn had acute respiratory failure in the first hours of life, requiring mechanical ventila-tion. The X- ray of the chest showed unilateral diaphragmatic paralysis and cardiomegaly. Discussion: diaphragmatic palsy in congenital Zika has not been previously reported, the etiopathogenic mechanisms of this event in congenital Zika virus needs to be elucidated.


Resumo Introdução: apesar de vários defeitos de nascimento associados à infecção congênita pelo Zika vírus terem sido descritos, o quadro clínico ainda não foi completamente caracterizado. Descrição: este é o primeiro relato de caso de paralisia diafragmática unilateral em um neonato com diagnóstico confirmado de Zika congênita pelo exame do líquido amniótico utilizando a reação da polimerase em cadeia (ZIKV PCR-RT) e pelo exame sorológico do líquido cefaloraquidiano (ZIKV IgM-ELISA), após o nascimento. As principais manifestações detectadas pela ultrassonografia intraútero no período gestacional foram: microcefalia, ventriculomegalia, calcificações intracranianas, cisterna magna alargada, aumento do índice de liquido amniótico e síndrome da acinesia fetal. O recém-nascido apresentou falência respiratória aguda nas primarias horas de vida, necessitando de ventilação mecânica. A radiografia de tórax realizada mostrou paralisia diafragmática unilateral e cardiomegalia. Discussão: a paralisia diafragmática na Zika congênita não havia sido previamente relatada, havendo a necessidade de investigação dos mecanismos etiopatogênicos dessa manifestação na infecção congênita pelo Zika vírus.


Assuntos
Humanos , Recém-Nascido , Anormalidades Congênitas , Paralisia Respiratória/diagnóstico , Infecção por Zika virus/congênito , Infecção por Zika virus/diagnóstico , Líquido Amniótico , Líquido Cefalorraquidiano , Doenças do Recém-Nascido , Microcefalia , Reação em Cadeia da Polimerase
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...